Descriptions of Vertical Block Mold JOBLOCK-H:
We are currently the only supplier with a complete range of vertical and horizontal block moulds with stepless length and/or height adjustment. All block moulds are equipped with our patented sliding door technology, which make them unbeatable in terms of cycle times. Symmetric media management in conjunction with the possibility of steam chamber purging ensures that you can convince your market of the quality of your blocks and plates.
Our hot-air vacuum will considerably reduce the formation of condensation and the moisture content in the blocks.
Main Technical Specifications of Vertical Block Mold JOBLOCK-H:
Throughput(in EPS blockss per hour) 2) |
|
1.0pd/ft3(approx.15g/l) |
Approx.16-24 |
1.2 pd/ft3(approx..20g/l) |
Approx.15-21 |
1.5 pd/ft3(approx..25g/l) |
Approx.12-16 |
Operating voltage |
3x400v |
Frequency |
50Hz |
Installed connection power |
Approx.55kw |
Approx.75hp |
|
Earthing |
Protective multiple earthing |
Regulations |
VDE |
Compressed air supply |
Min.6 bar |
Min.87 psi |
|
Compressed air connection |
1/2 " |
Pneumatic system |
Festo |
Steam supply-by customers |
Adjustable from 1.5-2.5 bar |
Adjustable from 22-36 psi |
|
Adjustable main steam over |
Somas |
Cold water supply |
4-6 bar |
Recommended cold water temperature |
<25。C |
<77。C |
|
Control components |
Siemens/Beckhoff |
Compressive stength |
100kpa 3) |
14.5Psi 3) |
|
Bulk density distribution |
+/-2.5% 4) |
Residual mositure in EPS block |
6 weight% 5) |
EPS block densities |
10-40g/l |
0.6-2.5pd/ft 3 |
|
| Water usage for operation with cold water system | about 15 m3/h |
| about 4000 gal/h 1) | |
Water usage for operation with cold water system |
Approx.5m3 for first fill |
Approx.1300 gal for first fill |
|
Water usage for operation with energy recovery |
0 m3/h |
0 gal/h |
|
Steam usage |
Approx.6-8kg per m3 of EPS produced |
Approx.13-18 pd per 35ft3 of EPS produced |
|
Compressed air usage of the block mold |
Approx.3-4 Nm3/h |
Block mold |
Approx.100-140ft3/h |